Enjoy FREE SHIPPING on every order, fully insured for your peace of mind.
XY-WT01 Temperature Controller Digital LED Display Heating/Cooling Regulator100% brand new and high qualityFeatures:Set Temperature --SetT Backlash Temperature--BackT1.Heating Mode HWhen Temperature SetT BackT Relay conduction, heating equipment begin to work WhenTemperature SetT,Relaydisconnect, heating equipment stop work 2.Refrigeration mode CWhen Temperature SetT+BackT Relay conduction, refrigeration equipment begin to work When Temperature SetT Relay conduction, refrigeration equipment stopwork 3.High Temperature Alarm ALAWhen Temperature AlarmTemperature,The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light 4.Delay Start OPHWhen a normal heating or refrigeration work is done, the system starts to time T, and only after the TOPH, the system can carry out the next round of heating or refrigeration work 5.Temperature Correction Function OFE(-10.0 ~ 10.0)The system will work for a long time and may have deviations that can be corrected by this function,Temperature = Measured + Calibration6.Parameter Remote Read/SetThe parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.7.Real-time Temperature Report:If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection 8.Relay enable (default enable):If the relay is disable, the relay remains disconnected 9.Restore factory Settings:At the same time press the STOP, set key more than 3S, restore factory settings Working modesetting /backlash temperature :1.In the running interface, short press SET key, enter the Quick setting interface 2.After entering the Quick Setup interface, switch the parameters3.Through theUP DOWN key, modify the parameter value, support short press/long press 4.Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly set the interface, and save parameters Alarm temperature/delay Start /temperature correction:1.In the operating interface, long press SET more than 3s, enter the parameters to set the interface 2.Enter the parameter to set the interface, through the short press SET key to switch to set the parameters 3.through the UP DOWN key, modify the parameter value, support short press/long press 4.Long press SET3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters How to turn on high temperature alarm (default off):Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the high temperature alarm function by short pressing the STOP button, and if the high temperature alarm function closes, ALA displays '----' as a reminder How to turn on delay start (default 0ff):Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high temperature alarm function by short Press STOP button, if high temperature alarm function closes, OPH show '---' to remind Serial Control (MCU UART)Communication standards: 9600bpsData bits: 8Stop Bits: 1CRC: noneFlow control: nonePackage includes:1 x XY-WT01 Temperature Controller
Enjoy FREE SHIPPING on every order, fully insured for your peace of mind.
Cancellation Policy:
We at Order2india strive to provide you with the best possible experience while you shop with us online. Since our orders are shipped from overseas , we try to reduce the handling time as much as possible by quickly processing the orders , Hence any cancellation request , has to be placed within 24 hours of placing the order. The refund amount will be credited back on your original mode of Payment. .
Warranty:
All our products comes with a default 90 days seller replacement warranty against manufacturer defect as a service and reassurance to our customers. Order2india will take care of all logistics to and from the manufacturer/supplier for replacement . If within 90 days of delivery ,any problem is found with our product , please contact our customer support and we would replace it for you absolutely free.
Return Policy
Our return policy is outlined below. The policy reflects the reality that our products are sourced from suppliers located outside India and is formulated keeping in mind the costs and time involved in the logistics, both in the forward direction (i.e. shipping products to India from the suppliers) and reverse direction (i.e. shipping returned products back to the suppliers).Certain products are not eligible for return or refund as below
Return Process & Timeline
For eligible products, the policy is summarized below. Please note that Returns that do not meet the Return Process and Timeline below will not be eligible for a refund.
|
|
Allowed Time Line |
Return Process |
|
Due to Damage in transit |
Within 24 hours of Delivery |
Inspect package before taking Delivery and if damaged REJECT package and DO NOT take delivery from the courier and Send email to support@order2india.com within 24 hours of rejecting the delivery so we can process your refund. |
|
Dead on Arrival or mal-functioning product |
Within 15 days of Delivery |
Contact us or email us at support@order2india.com within 15 days of delivery with details of the problem. |
|
Incorrect Order (e.g. model, brand, color or size different from what was ordered) |
Within 15 days of Delivery |
Contact us or email us at support@order2india.com within 7 days of delivery with details of the problem. |
We process your payment information securely. We do not store credit card details nor do we have access to your credit card information.
If you receive a parcel with missing, incorrect, or secondary packing items, please contact us within 7 days of delivery with relevant proof. Order2india will assess the situation and provide resolution based on the extent of the damage.