XKC-Y26-V Non-contact Water Liquid Level Sensor Induction Switch Detector 5-12V


Price:
Sale priceRs. 4,523.00

Description

XKC-Y26-V Non-contact Water Liquid Level Sensor Induction Switch Detector 5-12VThe liquid level sensor has no special requirements for liquid type and container materials and can be widely used.The installation is simple and does not affect the production.The output signal is High and Low LevelSpecifications:Product model:XKC-Y26-VInput voltage (Vin): DC 5~12VOutput Signal:High and Low LevelCurrent consumption: 5mAOutput voltage (high level): VinOutput voltage (low level): 0VOutput current: 1~100mAResponse time: 500mSWorking environment temperature: 0~85CHumidity: 5%~100%Material: ABSWaterproof performance: IP65SIze:18 x 13 x 11mmCable Length:45cmSensitivity:Pipe outer diameter D(mm) Sensing wall thickness L(mm) D 100, L: 202100100 80, L: 152 80100 60, L: 122 60100 40, L: 71 40100 30, L: 51 30100 20, L: 31 20100 10, L: 1.50.5Applicable pipe diameter range: 10mmLevel error: 1.5mmDescriptionIntelligent non-contact type level detector(Hereinafter referred to level detector) adopts advanced signal processing technology and high speed signal processing chip, break through the effects of vessel wall thickness, realized the real non-contact measurement for the level height in the sealed vessel. Level sensor(probe) installed on the top and bottom(the high level and the low level) of the measuring vessel wall, non-metal vessel do not need to drill a hole, easy installation, good for the production. Can be used for different kinds of toxic, strong acid, strong alkali, and all kinds of level measurement in the high pressure sealed vessel or tank. The application of this product is very wide, no special requirements for liquid media and vessel material.Product Feature1: XKC-Y26-V suitable for non-metal pipe wall, and do not need to contact the liquid, will not corrode by strong acid, strong alkali, and other corrosive liquid. Will not affected by incrustation or other impurities.2: Intelligent level adjustment and level memory function, level status display method, can realize multi points series connection,Feature:It achieves non-contact detection of the liquid level in the closed container.The liquid level sensor is installed on the upper and lower sides of the container (the liquid level is high and low)The non-metallic container does not need to open the hole. Can detect the level of various toxic substances, strong acids, alkalis and various liquids in high pressure airtight containersPackage include:1pc Non-contact Liquid Level Sensor1pc Fixed belt

Enjoy FREE SHIPPING on every order, fully insured for your peace of mind.

Cancellation Policy:

We at Order2india strive to provide you with the best possible experience while you shop with us online. Since our orders are shipped from overseas , we try to reduce the handling time as much as possible by quickly processing the orders , Hence any cancellation request , has to be placed within 24 hours of placing the order. The refund amount will be credited back on your original mode of Payment. . 

Warranty:

All our products comes with a default 90 days seller replacement warranty against manufacturer defect as a service and reassurance to our customers. Order2india will take care of all logistics to and from the manufacturer/supplier  for replacement . If within 90 days of delivery ,any problem is found with our product , please contact our customer support and we would replace it for you absolutely free.

Return Policy

Our return policy is outlined below. The policy reflects the reality that our products are sourced from suppliers located outside India and is formulated keeping in mind the costs and time involved in the logistics, both in the forward direction (i.e. shipping products to India from the suppliers) and reverse direction (i.e. shipping returned products back to the suppliers).Certain products are not eligible for return or refund as below

Return Process & Timeline


For eligible products, the policy is summarized below. Please note that Returns that do not meet the Return Process and Timeline below will not be eligible for a refund.

 


Reason

Allowed Time Line

Return Process

Due to Damage in transit

Within 24 hours  of  Delivery

Inspect package before taking Delivery and if damaged REJECT package and DO NOT take delivery from the courier and Send email to support@order2india.com within 24 hours of rejecting the delivery so we can process your refund.

Dead on Arrival or mal-functioning product

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 15 days of delivery with details of the problem. 
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

Incorrect Order (e.g. model, brand, color or size different from what was ordered)

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 7 days of delivery with details of the problem.
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

We process your payment information securely. We do not store credit card details nor do we have access to your credit card information.

If you receive a parcel with missing, incorrect, or secondary packing items, please contact us within 7 days of delivery with relevant proof. Order2india will assess the situation and provide resolution based on the extent of the damage.

You may also like

Recently viewed

Free delivery

Providing Free Delivery Across India

Top-notch support

Any Queries, Contact us Anytime at Support@order2india.com