TB6600 Upgrade Version 4.0A 42V DC 32 Subdivision 42/57/86 Stepper Motor Driver


Price:
Sale priceRs. 1,449.00

Description


1. 9V-40V DC power supply
2. H-bridge bipolar constant phase current driver
3. Up to 4.0A eight output current selectable
4. 6 sub-division modes up to 32 sub-divisions selectable
5. Input signal high-speed optical isolation
6. Standard common positive single pulse interface
7. Offline hold function
8. Semi-enclosed enclosure for more demanding environments
9. Provide energy-saving semi-automatic current lockout function
10. Built-in temperature protection and over-current protection
11. Applicable stepping motor: 42, 57, 86 type 2-phase 4-phase (4 wire 6 wire 8 wire)
12. Weight: about 201g

Wiring terminal definition description:
-Signal input terminal:
1. CP+: pulse signal input positive terminal
2. CP-: pulse signal input negative terminal
3. DIR+: motor forward and reverse control positive terminal
4. DIR-: motor forward and reverse control negative terminal
5. EN+: motor offline control positive terminal
6. EN-: motor offline control negative terminal

-Motor winding connection:
1. A+: connect motor winding A+ phase
2. A-: connect to motor winding phase A-
3. B+: connect motor winding B+ phase
4. B-: connect motor winding B- phase

-Connections for operating voltage:
1. VCC: DC power supply positive ( note: 10V <VCC <42V)
2. GND: DC power supply negative

-Input signal interface has two connection methods: users can use the common anode connection method or common cathode connection method according to the need
1. Common anode connection: connect CP+, DIR+ and EN+ to the power supply of the control system, if the power supply is +5V, then it can be connected directly, if the power supply is greater than +5V, then it is necessary to add another external current limiting resistor R, to ensure that the internal optical coupler of the driver can provide a driving current of 8-15mA. pulse input signal through the CP-access; at this time, DIR-, EN- in the low level of active
2. Common cathode connection: connect CP-, DIR- and EN- to the ground of the control system (SGND, isolated from the power supply ground); the +5V pulse input signal is added through CP+; at this time, DIR+ and EN+ are active at high level. the value of current limiting resistor R is the same as that of common anode connection
3. Note: the EN terminal may not be connected, the motor rotor is in a free state (offline state) when EN is valid, then you can manually rotate the motor rotor to do the adjustment that suits you. after the manual adjustment is completed, set EN to invalid state to continue the automatic control

Enjoy FREE SHIPPING on every order, fully insured for your peace of mind.

Cancellation Policy:

We at Order2india strive to provide you with the best possible experience while you shop with us online. Since our orders are shipped from overseas , we try to reduce the handling time as much as possible by quickly processing the orders , Hence any cancellation request , has to be placed within 24 hours of placing the order. The refund amount will be credited back on your original mode of Payment. . 

Warranty:

All our products comes with a default 90 days seller replacement warranty against manufacturer defect as a service and reassurance to our customers. Order2india will take care of all logistics to and from the manufacturer/supplier  for replacement . If within 90 days of delivery ,any problem is found with our product , please contact our customer support and we would replace it for you absolutely free.

Return Policy

Our return policy is outlined below. The policy reflects the reality that our products are sourced from suppliers located outside India and is formulated keeping in mind the costs and time involved in the logistics, both in the forward direction (i.e. shipping products to India from the suppliers) and reverse direction (i.e. shipping returned products back to the suppliers).Certain products are not eligible for return or refund as below

Return Process & Timeline


For eligible products, the policy is summarized below. Please note that Returns that do not meet the Return Process and Timeline below will not be eligible for a refund.

 


Reason

Allowed Time Line

Return Process

Due to Damage in transit

Within 24 hours  of  Delivery

Inspect package before taking Delivery and if damaged REJECT package and DO NOT take delivery from the courier and Send email to support@order2india.com within 24 hours of rejecting the delivery so we can process your refund.

Dead on Arrival or mal-functioning product

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 15 days of delivery with details of the problem. 
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

Incorrect Order (e.g. model, brand, color or size different from what was ordered)

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 7 days of delivery with details of the problem.
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

We process your payment information securely. We do not store credit card details nor do we have access to your credit card information.

If you receive a parcel with missing, incorrect, or secondary packing items, please contact us within 7 days of delivery with relevant proof. Order2india will assess the situation and provide resolution based on the extent of the damage.

You may also like

Recently viewed

Free delivery

Providing Free Delivery Across India

Top-notch support

Any Queries, Contact us Anytime at Support@order2india.com