{"product_id":"m6013-auto-range-digital-capacitor-capacitance-tester-meter-cap-0-01pf-to-47mf-orange","title":"M6013 Auto Range Digital Capacitor Capacitance Tester Meter Cap 0.01pF to 47mF(Orange)","description":"Features: \u003cbr\u003e\u003cbr\u003eJINGYAN M6013 V2 Auto-ranging capacitance meter. \u003cbr\u003e\u003cbr\u003eUsing 128X64 dot matrix LCD, can display 5 digit reading, Large range of measuring 0.01pF to 470mF (470000uF) capacitance, which enough for DIY user to professional engineer usage. \u003cbr\u003e\u003cbr\u003eM6013 have fast reading speed and high accuracy up to 1%. \u003cbr\u003e\u003cbr\u003eReading a 2200uF only take ~0.2s \u003cbr\u003e\u003cbr\u003ePLEASE DISCHARGE THE CAPACITOR BEFORE TESTINGã€€ \u003cbr\u003e\u003cbr\u003eCompare M6013 old V1 and new V2 Improvement: \u003cbr\u003e\u003cbr\u003e1) Larger measuring range, V2 can read up to 470mF \u003cbr\u003e\u003cbr\u003e2) New large dot matrix LCD \u003cbr\u003e\u003cbr\u003e3) More stable on reading, (with auto running averaging function, can read pF more stable and accuracy) \u003cbr\u003e\u003cbr\u003e4) New housing with stand \u003cbr\u003e\u003cbr\u003e5) Can use 2X AA battery rather than 9V \u003cbr\u003e\u003cbr\u003e6) Can use mirco usb as external power. \u003cbr\u003e\u003cbr\u003eSpecification: \u003cbr\u003e\u003cbr\u003eRange  \u003cbr\u003e\u003cbr\u003e Accuracy (After Zero, tested with 1nF, 1uF, 1000uF)  \u003cbr\u003e\u003cbr\u003e Refresh Time  (Manual Mode)  \u003cbr\u003e\u003cbr\u003eAuto mode take 0 to 2s more time depend on value \u003cbr\u003e\u003cbr\u003eLarger capacitance take more measuring time  \u003cbr\u003e\u003cbr\u003e0.01pF to 47.000nF 1%+2Digit  ~0.2s to 1s  \u003cbr\u003e\u003cbr\u003e47.00nF to 47.000uF 1%+1Digit  ~0.2s to 2s  \u003cbr\u003e\u003cbr\u003e47.00uF to 470.00mF 1 to 3%+1Digit (Larger capacitance will have larger error)  \u003cbr\u003e\u003cbr\u003e ~0.2s to 30s  \u003cbr\u003e\u003cbr\u003eAccuracy maybe affected by the test leadâ€™s length and distance of test leads. Especially testing pF small capacitance, shortest test lead is recommended, and be careful the surrounding EMI or RF noise may affect the pF reading. \u003cbr\u003e\u003cbr\u003e1) Accuracy:  Up to 1% (detail on above table) \u003cbr\u003e\u003cbr\u003e2) High Resolution: 5 digit \u003cbr\u003e\u003cbr\u003e3) Measuring voltage: \u0026lt;0.8V \u003cbr\u003e\u003cbr\u003e4) Clamping voltage: ~1.25V (open voltage) \u003cbr\u003e\u003cbr\u003e5) Battery 2X AA 1.5V battery \u003cbr\u003e\u003cbr\u003e6) External Power: 5V micro USB \u003cbr\u003e\u003cbr\u003e7) Operating current 0.02A \u003cbr\u003e\u003cbr\u003e8) Battery Life time: \u0026gt;80 Hours \u003cbr\u003e\u003cbr\u003eOperating Introduction: \u003cbr\u003e\u003cbr\u003e1) POWER ON \u003cbr\u003e\u003cbr\u003ePress and hold the ON\/ OFF circle orange button for 1 to 2 second to power on. \u003cbr\u003e\u003cbr\u003ePress and release the ON\/ OFF button to shut down meter. \u003cbr\u003e\u003cbr\u003e2) AUTO\/ MANUAL mode: \u003cbr\u003e\u003cbr\u003eAuto Range: \u003cbr\u003e\u003cbr\u003ePress and release the RANGE button and at the first line of LCD will show â€œAUTO:\" \u003cbr\u003e\u003cbr\u003eAt auto mode meter will automatically select the best range to detect. \u003cbr\u003e\u003cbr\u003eManual Range: \u003cbr\u003e\u003cbr\u003eScroll the manual range from 47nF, 47uF and 470mF range by press and release the RANGE button \u003cbr\u003e\u003cbr\u003eIn LCD will show MANUAL at first LCD line and show at second line: 0-47NF, 47NF TO 47UF and 47UF TO 470MF. \u003cbr\u003e\u003cbr\u003e3) 1 Key Zero: \u003cbr\u003e\u003cbr\u003eOPEN circuit the test leadsâ€™ terminal. \u003cbr\u003e\u003cbr\u003ePress and release the â€œZERO\" button, LCD shows â€œZERO\" and wait the zero disappear. \u003cbr\u003e\u003cbr\u003eIf you are using the meter array socket, you need to OPEN circuit to set zero too. \u003cbr\u003e\u003cbr\u003e4) Socket: \u003cbr\u003e\u003cbr\u003eYou can use the 8 pin socket to measure the capacitor  \u003cbr\u003e\u003cbr\u003e5) Running Average: \u003cbr\u003e\u003cbr\u003eIt will automatically start running average if the capacitance reading become stable and user can get more accuracy reading. \u003cbr\u003e\u003cbr\u003eDuring running average it will show â€œAVGâ€ at right bottom LCD or it will show raw data icon â€œRAWâ€ \u003cbr\u003e\u003cbr\u003eAs a result, if you want to get higher accuracy reading, you can take the reading during AVG display. \u003cbr\u003e\u003cbr\u003eThis function will automatically on, once the raw data is noise. \u003cbr\u003e\u003cbr\u003e6) Backlight: \u003cbr\u003e\u003cbr\u003eLCD backlight will on during power on \u003cbr\u003e\u003cbr\u003e7) Auto Sleep: \u003cbr\u003e\u003cbr\u003eAround 8 to 10 hours for not testing, it will shut down automatically to save power. \u003cbr\u003e\u003cbr\u003e8) OVERFLOW or OL: \u003cbr\u003e\u003cbr\u003eDisplay overflow when the value is out of range, you can check that you are zero correctly. \u003cbr\u003e\u003cbr\u003e9) PLASTIC STAND: \u003cbr\u003e\u003cbr\u003eIf you donâ€™t use the stand, press and push the lock position","brand":"O2I24","offers":[{"title":"Default Title","offer_id":43734756032634,"sku":"S-DT-0512","price":4139.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0929\/2582\/files\/S-DT-0512.jpg?v=1707915816","url":"https:\/\/order2india.com\/products\/m6013-auto-range-digital-capacitor-capacitance-tester-meter-cap-0-01pf-to-47mf-orange","provider":"ORDER2INDIA SHOPPING","version":"1.0","type":"link"}