0.1-60MHz RF Signal Frequency Counter 20MHz~2.4GHz Cymometer Tester Led Display


Price:
Sale priceRs. 5,955.00

Description

ITEM NAME:0.1-60MHz RF Signal Frequency Counter 20MHz~2.4GHz Cymometer Tester Led Display 0.1-60MHz RF Signal Frequency Counter 20MHz~2.4GHz Cymometer Tester Led Display Description: With Microchip's PIC16F648A, 2.4 GHz frequency meter. Using temperature-compensated voltage controlled crystal oscillator (2.5 ppm VC-TCXO). Unique gate control and precise time algorithm (non-timed interrupt). Gate (display refresh) time 0.01 seconds / 0.1 seconds / 1.0 seconds, real-time display frequency value. Single-ended input design, three-channel frequency measurement (low channel / high channel / Auto Channel). Dual frequency design, value and IF / down mode can be preset separately. Using eight 0.56 inches high brightness digital display, eight adjustable brightness. Circuit is simple and reasonable structure, two-button control, simple operation. The settings are automatically saved, boot directly call. 1 Gate time 0.01s 0.10s 1.0s 2 Measurement channels (channels are low impedance) low channel Measuring range: 0.1 MHz ~ 60 MHz Accuracy: ± 100Hz (0.01 1s gate time) ± 10Hz (0.1 seconds gate) ± 1Hz (1.0 seconds when the gate) Low channel sensitivity: 0.1 MHz ~ 10 MHz: better than 60mVPP 10 MHz ~ 60 MHz: better than 60mVPP 60 MHz ~ 75 MHz: Not tested high channel (divided by 64) Measuring range: 20 MHz ~ 2.4 GHz Accuracy: ± 6400Hz (0.01 seconds gate) ± 640Hz (0.1 1s gate time) ± 64Hz (1.0 1s gate time) High channel sensitivity: 20 MHz ~ 30 MHz: better than 100mVPP 30 MHz ~ 60 MHz: better than 50mVPP 60 MHz ~ 2.4GHz: not tested Auto Channel Automatically selected according to the input signal frequency high or low channel channel, identifying the frequency of 60 MHz. Such as when the input signal amplitude is greater than 60 MHz shortage can not automatically select high channel, the channel should manually select high frequency measurement. 3. IF settings Independent double-IF design, adjust the minimum frequency step of 100 Hz,frequency range 0 ~ 99.9999 MHz, can be set to incr.Find many great new & used options and get the best deals for 0.1-60MHz RF Signal Frequency Counter 20MHz~2.4GHz Cymometer Tester Led Display at the best online prices at Order2india Shopping! Free shipping for many products!

Enjoy FREE SHIPPING on every order, fully insured for your peace of mind.

Cancellation Policy:

We at Order2india strive to provide you with the best possible experience while you shop with us online. Since our orders are shipped from overseas , we try to reduce the handling time as much as possible by quickly processing the orders , Hence any cancellation request , has to be placed within 24 hours of placing the order. The refund amount will be credited back on your original mode of Payment. . 

Warranty:

All our products comes with a default 90 days seller replacement warranty against manufacturer defect as a service and reassurance to our customers. Order2india will take care of all logistics to and from the manufacturer/supplier  for replacement . If within 90 days of delivery ,any problem is found with our product , please contact our customer support and we would replace it for you absolutely free.

Return Policy

Our return policy is outlined below. The policy reflects the reality that our products are sourced from suppliers located outside India and is formulated keeping in mind the costs and time involved in the logistics, both in the forward direction (i.e. shipping products to India from the suppliers) and reverse direction (i.e. shipping returned products back to the suppliers).Certain products are not eligible for return or refund as below

Return Process & Timeline


For eligible products, the policy is summarized below. Please note that Returns that do not meet the Return Process and Timeline below will not be eligible for a refund.

 


Reason

Allowed Time Line

Return Process

Due to Damage in transit

Within 24 hours  of  Delivery

Inspect package before taking Delivery and if damaged REJECT package and DO NOT take delivery from the courier and Send email to support@order2india.com within 24 hours of rejecting the delivery so we can process your refund.

Dead on Arrival or mal-functioning product

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 15 days of delivery with details of the problem. 
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

Incorrect Order (e.g. model, brand, color or size different from what was ordered)

Within 15 days  of Delivery

Contact us or email us at support@order2india.com within 7 days of delivery with details of the problem.
Product(s) must be re-packed in original packing along with all the material, manual that came alone with the order).

We process your payment information securely. We do not store credit card details nor do we have access to your credit card information.

If you receive a parcel with missing, incorrect, or secondary packing items, please contact us within 7 days of delivery with relevant proof. Order2india will assess the situation and provide resolution based on the extent of the damage.

You may also like

Recently viewed

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Free delivery

Providing Free Delivery Across India

Top-notch support

Any Queries, Contact us Anytime at Support@order2india.com